Automatic electronic water pump pressure switch adjustable pressure control MK-WPPS12 with the plug socket wires
$44.91
199 in stock
Description
- Brand Name: makerele
- Certification: CCC,CE,RoHS
- Warranty: Water Pump Pressure switch
- Switch Type: Pressure Switch
- Model Number: Water Pump Pressure switch
- Features: Water Pump Pressure switch
- Material: Plastic
- Current: 10A
- Item Type: Switches
- Place of Origin: Zhejiang China (Mainland)
- Starting pressure setting: 1.2bar-2.2bar
- Connection thread: G1″
- Frequency: 50/60Hz
- Max Ambient Temperature: 60
- Protection Degree: IP65
- used in: water pump
|
||||||||||||||||||
|
||||||||||||||||||
Please Care for the Voltage,Phase,Joint Screw,Starting pressure setting and So on. If not problem,we will send regular Product to you.
1.adjustable pressure control
2. Model: MK-WPPS12
3. used for water Pump
4.Female&male:1/4 NPT
2. Protect the pump from damage caused by dry-running
adjustable pressure control TECHNICAL DATE
1.Starting Pressure:1.2bar-3bar
2.Max Rate Current:10A
3.Max Allowable Pressure:10 Bar
4.Rated Voltage:220v-240V
5.Frequency:50/60Hz
6.Max Temperature:60C
7.Protection Degree:IP65
8.Max Power: 1.1kw,1.5kw
adjustable pressure control DESCRIPTIONS
This automatic pumpo control is mainly used in household for controlling the running of pump.Joint screw:G1″male
1.It start the electric pump automatically after a pressure decrease(taps opening)and stops it when the fluid flow interrupts at the maximum pressure level of the electric pump(taps closed),keep the household water supply system in water supply state with a constant pressure.
2.Protect the pump, in the case of water shortage or jam,it is able to indentify these fault and at the same time stop the pump

adjustable pressure control Size:
2014 Year All pressure switch :
- 1. Item will be shipped within 5-7 business days.
- 2. Delivery Time:
- —-Via Air: Generally 1-3 working days
- —-Via Express: Generally 3-7 working days.
- —-Via China Post Air Mail: Generally 15-25 working days
- —-Via Sea: According to the order.
- 3.If you have not received your shipment within 30 days from payment,Please contact with us,We will track the shipment and get back to you as soon as possible with a reply.
Maker Industrial and Trading Company started to run businiess since 2006, which is located in Wenzhou Yueqing – The world-famous city for low-voltage electric apparatus.
- Custom Product Design
- OEM/ODM
- Profession in export service from Maker Electric
- High quality Product, Affordable Price
What are the Usual Water Pump and Tank Pressure Control Settings in PSI?
Most residential water systems using a water pressure tank and water pump use one of these two pressure operating ranges:
Low-pressure operating range pumps like low horsepower pumps and many jet pumps
- Cut in (start pumping) – 20 psi
- Cut out (stop pumping) – 40 psi
Higher-pressure water pumps, like submersible pumps, and higher horsepower 2-line jet pumps
- Cut in (start pumping) – 30 psi
- Cut out (stop pumping) – 50 psi
How High Can we Set the Water Pressure in My Building?
You can’t just set the pump pressure as high as you want to. Here’s what can go wrong with excessive pump pressure control settings:
- Exceeding well pump pressure capability: If you set the cut out (stop pumping) pressure higher than the water pump is capable of reaching, the pump will just keep running indefinitely until it burns up or blows a fuse or trips a circuit breaker or overheats.
- Causing a ruptured water tank internal bladder: we have had a number of reports of ruptured bladders in water tanks. In normal use the bladder in most water tanks is not stressed at all – the internal water tank bladder simply moves up and down as water enters or leaves the tank – pressure on either side of the bladder (air on one side, water on the other side) remains the same.
If your water tank were a less common model in which air were inside the bladder rather than outside it, excessive air pressure could burst the bladder. If you set the water pump pressure too high on one of these systems, you might cause the water bladder to rupture inside the tank. In an extreme case you might blow up the water tank itself. Most water tanks are not designed this way.
- Blowing up a water pressure tank – serious safety hazard: if you set water pressure too high, even if the pump is capable of reaching that pressure it may be unsafe. Most water pressure tanks are designed to operate safely in the water pressure ranges we cited above. If you had the bad luck (and stupidity) as to be using a water tank that has no pressure relief valve installed, it is possible to cause the tank to rupture or even explode, risking damage to the building or even serious injury or fatality if anyone is nearby.
- Causing leaks at fixtures: even if your water tank were rated for high pressure, and even if your water pump is capable of high water pressure, if you run water pressure in a building over 70 or 80 psi you can expect to have recurrent leaks at plumbing fixtures: most water faucets and tub faucets are not designed for high pressure use.
|
||||||||